Заказать звонок
Меню

Главная Каталог Документация Новости Оплата Доставка О компании Контакты

Output Expansions

ID каталога
Группа продукта
Страна происхождения
3SK1211-2BW20
3SK1211-2BW20
Заказной номер: 3SK1211-2BW20
SIRIUS SAFETY RELAY OUTPUT EXTENSION 4RO WITH RELAY ENABLING CIRCUITS 4 NO CONTACTS + RELAY FEEDBACK CIRCUIT 1 NC CONTACT US = 110-240 V AC/DC SPRING-LOADED CONNECTION
3SK1211-1BB40
3SK1211-1BB40
Заказной номер: 3SK1211-1BB40
SIRIUS SAFETY RELAY OUTPUT EXTENSION 4RO WITH RELAY ENABLING CIRCUITS 4 NO CONTACTS + RELAY FEEDBACK CIRCUIT 1 NC CONTACT US = 24 V DC SCREW CONNECTION
3SK1213-2AB40
3SK1213-2AB40
Заказной номер: 3SK1213-2AB40
SIRIUS SAFETY RELAY OUTPUT EXTENSION 3RO POWER, WITH RELAY ENABLING CIRCUITS 3 NO CONTACTS + RELAY FEEDBACK CIRCUIT 1 NC CONTACT US = 24 V DC SPRING-LOADED CONNECTION
3SK1213-2AL20
3SK1213-2AL20
Заказной номер: 3SK1213-2AL20
SIRIUS SAFETY RELAY OUTPUT EXTENSION 3RO POWER, WITH RELAY ENABLING CIRCUITS 3 NO CONTACTS + RELAY FEEDBACK CIRCUIT 1 NC CONTACT US = 230 V AC SPRING-LOADED CONNECTION
3SK1211-1BB00
3SK1211-1BB00
Заказной номер: 3SK1211-1BB00
SIRIUS SAFETY RELAY OUTPUT EXTENSION 4RO WITH RELAY ENABLING CIRCUITS 4 NO CONTACTS + RELAY FEEDBACK CIRCUIT 1 NC CONTACT US = 24 V AC SCREW CONNECTION
1
2 3

Обзор

3SK121 output expansions can be used to expand any 3SK basic device.

3SK1211 output expansion

A 3SK1211 output expansion is used to expand the safe circuits of a basic unit by adding another four safe circuits. These outputs have a switching capacity of AC-15 5 A at a switching voltage of 230 V. The devices can be connected to any 3SK basic unit by means of wiring. In addition, devices with a 24 V DC control supply voltage can also be connected to 3SK1 Advanced basic units and 3SK2 basic units using 3ZY12 device connectors.

3SK1213 output expansion

A 3SK1213 output expansion is used to expand the safe outputs of a basic unit by adding three safe outputs with high switching capacity. These outputs have a switching capacity of AC-15 10 A at a switching voltage of 230 V. The devices can be connected to any 3SK basic unit by means of wiring. As with 3SK1211, it is also possible to connect the version with a 24 V DC control supply voltage to the 3SK1 Advanced basic units and 3SK2 basic units on the 3ZY12 device connector.

Note:

It is only possible to expand the Standard basic units my means of wiring. Advanced basic units can be expanded using the 3ZY12 device connector.

Number of safe outputs
 

Type and number of safe outputs

Signaling circuits

Device connectors

 

Relays

  

 

Instantaneous

Time-delayed

  

3SK output expansions

  • 4RO

3SK1211

4

--

11)

✓2)

  • 3RO

3SK1213

3

--

11)

✓2)



✓ Available

-- Not available

1) Feedback circuit

2) For 24 V DC.